{"product_id":"warrior-ldg6500sv-5kw-silent-diesel-generator","title":"Warrior LDG6500SV 5.5kW Silent Diesel Generator","description":"\u003cp\u003e\u003cstrong\u003eWhen the lines go down, turn a key and get 5kW of diesel power back.\u003c\/strong\u003e The Warrior LDG6500SV keeps an oil boiler, borehole pump and the rest of your essentials running from a soundproofed canopy, with up to 12.4 hours from a half-loaded tank. It also has a port ready for automatic start, which the remote-control version doesn't.\u003c\/p\u003e\n\u003cp\u003e✔ Authorised UK reseller   ✔ Free delivery to mainland UK   ✔ Prices include VAT   ✔ 2-year warranty\u003c\/p\u003e\n\u003ch3\u003eWhy buyers choose the LDG6500SV\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5kW continuous, 5.5kW maximum.\u003c\/strong\u003e A 474cc direct-injection diesel engine, EU Stage V compliant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReady for automatic start.\u003c\/strong\u003e The built-in ATS input links to the optional Warrior ATS panel, which starts the generator when the mains fails and stops it when power returns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA long run on one tank.\u003c\/strong\u003e Up to 12.4 hours at 50% load from 16 litres, with a fuel gauge so you can plan ahead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtected as standard.\u003c\/strong\u003e Low-oil shutdown guards the engine, overload protection guards the output, and AVR holds the voltage steady.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuieter by design.\u003c\/strong\u003e A soundproof canopy and anti-vibration mountings bring it to 68 dB(A) at 7m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple to run.\u003c\/strong\u003e Electric key start, an electric fuel pump, and a 3-in-1 display for voltage, frequency and run time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo voltages.\u003c\/strong\u003e One 240V 32A outlet and one 110V 32A outlet, plus a 12V terminal for charging car-type batteries.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIs it right for you?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for:\u003c\/strong\u003e power cut backup at rural homes, off-grid and island properties, oil boilers and borehole pumps, small premises, and occasional construction or catering jobs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLook elsewhere if:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou'd rather start it from a key fob. The \u003ca href=\"\/products\/warrior-ldg6500svwrc-5kw-remote-start-silent-diesel-generator\"\u003eremote start LDG6500SVWRC\u003c\/a\u003e does that, but has no ATS input for automatic start.\u003c\/li\u003e\n\u003cli\u003eYou want longer between refuels. The \u003ca href=\"\/products\/hyundai-dhy8000selr-5-8kw-long-run-silent-diesel-generator\"\u003eHyundai DHY8000SELR Long Run\u003c\/a\u003e is built for it.\u003c\/li\u003e\n\u003cli\u003eYou mainly run laptops and other sensitive electronics. AVR helps, but an \u003ca href=\"\/products\/hyundai-hy6250sei-5-5kw-electric-start-petrol-inverter-generator\"\u003einverter generator\u003c\/a\u003e gives cleaner power.\u003c\/li\u003e\n\u003cli\u003eYou need three-phase. See our \u003ca href=\"\/collections\/three-phase-generators\"\u003ethree-phase generators\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eYou need power every day. This is a 3000rpm generator for backup and infrequent use, so ask us about a 1500rpm set.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat will it run?\u003c\/h3\u003e\n\u003cp\u003ePlan around the \u003cstrong\u003e5kW continuous\u003c\/strong\u003e output. The 5.5kW maximum is only for short bursts, and the manual says never to run at maximum for longer than 10 minutes. Motors can draw three times their running watts or more when starting, so check the rating plates on your own equipment.\u003c\/p\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAppliance\u003c\/th\u003e\n\u003cth\u003eTypical running watts\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED lighting, whole home\u003c\/td\u003e\n\u003ctd\u003e100 to 300W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRouter, TV and chargers\u003c\/td\u003e\n\u003ctd\u003earound 200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFridge freezer (higher start-up draw)\u003c\/td\u003e\n\u003ctd\u003e150 to 300W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil-fired boiler and pump\u003c\/td\u003e\n\u003ctd\u003earound 250W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBorehole pump (much higher start-up draw)\u003c\/td\u003e\n\u003ctd\u003e750 to 1,500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicrowave\u003c\/td\u003e\n\u003ctd\u003e1,200 to 1,600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWashing machine\u003c\/td\u003e\n\u003ctd\u003e2,100 to 2,400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKettle\u003c\/td\u003e\n\u003ctd\u003e2,500 to 3,000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectric shower\u003c\/td\u003e\n\u003ctd\u003e7,500W and up: too much for this generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRural home example:\u003c\/strong\u003e oil boiler 250W + 1,000W borehole pump + fridge freezer 150W + lights 100W + TV and router 200W comes to about 1,700W, which leaves around 3,300W in hand. If the pump pulls three times its running watts as it starts, the brief peak is about 3,700W, still inside the 5kW rating. Start the pump first, then bring on other loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOn the 110V outlet:\u003c\/strong\u003e expect only around 50 to 60% of the rated output, so about 2.5 to 3kW.\u003c\/p\u003e\n\u003ch3\u003eHow long will the fuel last?\u003c\/h3\u003e\n\u003cp\u003eAt half load, a 24-hour power cut will take about two full tanks, or 32 litres. Lighter loads last longer and heavier loads less. Keeping fuel on site makes sense if you're rural, and a \u003ca href=\"\/products\/sealey-jc20b-20-litre-black-steel-jerry-can\"\u003e20-litre steel jerry can\u003c\/a\u003e is a good start.\u003c\/p\u003e\n\u003cp\u003eUse clean light diesel only. Never use petrol, kerosene or biodiesel. Warrior doesn't recommend dyed diesel, such as red diesel, and if you do use it, the manual strongly recommends monthly maintenance.\u003c\/p\u003e\n\u003ch3\u003eConnecting it to your property\u003c\/h3\u003e\n\u003cp\u003eTo power your property's circuits, the generator must connect through a transfer switch fitted by a qualified electrician, so that it and the mains can never be connected together. Never feed it through a socket. Neither switch is included.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual switch:\u003c\/strong\u003e you start the generator and turn the switch yourself.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/warrior-diesel-ats-100a-automatic-transfer-switch-for-4kw-to-12kw-generators\"\u003eWarrior ATS panel\u003c\/a\u003e (part 190102000010):\u003c\/strong\u003e starts the generator for you and stops it when the mains returns, which suits properties often left empty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant for your warranty:\u003c\/strong\u003e Warrior's terms say that any manual or automatic transfer system not supplied under the Warrior or Champion name will invalidate all warranties. Please speak to us before you buy or install one.\u003c\/p\u003e\n\u003ch3\u003eWhere to put it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eChoose a flat, level, solid base outdoors, at least 1.5m from buildings, structures, windows and doors.\u003c\/li\u003e\n\u003cli\u003eIt isn't waterproof, so it must never be exposed to rain, snow or water spray. Plan this before it arrives.\u003c\/li\u003e\n\u003cli\u003eNever run it in a shed, garage, outbuilding or vehicle. As well as being dangerous, Warrior's terms exclude this from the warranty.\u003c\/li\u003e\n\u003cli\u003e68 dB(A) at 7m is quieter than an open-frame diesel, but you'll still clearly hear it, so keep it away from bedrooms and neighbours.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGetting it running\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDelivery:\u003c\/strong\u003e at 168kg it arrives on a pallet, so have a pallet truck or mechanical lifting ready. The wheels are for firm, level ground only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd engine oil.\u003c\/strong\u003e It's shipped dry and takes 1.1L. Warrior recommends 10W-30 part or full synthetic. Check the dipstick on level ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd clean diesel,\u003c\/strong\u003e and check the fuel line for air, as the manual describes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the battery\u003c\/strong\u003e is connected before first start.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth it.\u003c\/strong\u003e The manual recommends heavy wire from the earth terminal to a rod or stake at least 200mm deep. The rod isn't listed as included.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart with no load attached,\u003c\/strong\u003e then let it settle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRun it in gently.\u003c\/strong\u003e Keep below 75% load for the first 10 to 20 hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse the right plugs.\u003c\/strong\u003e The outlets are 32A industrial-style sockets, so use matching plugs, a transfer switch, or a suitable splitter box for 13A appliances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery note:\u003c\/strong\u003e Warrior generators can take 2 to 5 working days to arrive. If you need one by a certain date, please contact us before ordering and we'll confirm availability.\u003c\/p\u003e\n\u003ch3\u003eKeeping it ready\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eWhen\u003c\/th\u003e\n\u003cth\u003eWhat the manual asks for\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBefore each use\u003c\/td\u003e\n\u003ctd\u003eCheck oil and fuel, look for leaks and loose parts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAfter the first 20 hours\u003c\/td\u003e\n\u003ctd\u003eFirst oil change, drain the fuel tank, check valve clearances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonthly\u003c\/td\u003e\n\u003ctd\u003eCheck battery fluid and air filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvery 100 hours or 3 months\u003c\/td\u003e\n\u003ctd\u003eChange oil, clean oil filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvery 300 hours or 6 months\u003c\/td\u003e\n\u003ctd\u003eReplace oil and air filters, clean fuel filter, further engine checks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvery 1,000 hours or annually\u003c\/td\u003e\n\u003ctd\u003eReplace fuel filter, further engine servicing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eStart it regularly between power cuts so that it's ready when you need it. Some items need a service engineer, and the manual marks which ones.\u003c\/p\u003e\n\u003ch3\u003eFull specification\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eWarrior LDG6500SV (Bimson Power range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eCanopied silent diesel generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum output\u003c\/th\u003e\n\u003ctd\u003e5.5kW \/ 6.25kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContinuous output\u003c\/th\u003e\n\u003ctd\u003e5.0kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEngine\u003c\/th\u003e\n\u003ctd\u003e474cc, single cylinder, air-cooled, direct injection, 3000rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmissions\u003c\/th\u003e\n\u003ctd\u003eEU Stage V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlternator\u003c\/th\u003e\n\u003ctd\u003eBrushed copper, AVR regulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStart\u003c\/th\u003e\n\u003ctd\u003eElectric key start; ATS input port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage \/ phase\u003c\/th\u003e\n\u003ctd\u003e240V and 110V, single phase, 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutlets\u003c\/th\u003e\n\u003ctd\u003e1 x 240V 32A, 1 x 110V 32A, 12V DC charging terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eAutomatic low-oil shutdown, overload protection, AVR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e3-in-1: voltage, frequency and run time; fuel gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel \/ tank\u003c\/th\u003e\n\u003ctd\u003eLight diesel \/ 16 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRun time\u003c\/th\u003e\n\u003ctd\u003eUp to 12.4 hours at 50% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise\u003c\/th\u003e\n\u003ctd\u003e68 dB(A) at 7m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOil\u003c\/th\u003e\n\u003ctd\u003e1.1L, 10W-30 part or full synthetic recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWheels\u003c\/th\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e168kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e880 x 590 x 730mm (L x W x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIn the box\u003c\/th\u003e\n\u003ctd\u003eGenerator and operating manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eEU Stage V, UKCA, GS, TUV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years domestic: year 1 parts and labour, year 2 parts only, or 1,000 hours if sooner. Subject to manufacturer's terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs it really silent?\u003c\/strong\u003e \"Silent\" is the name for this canopied design. It's much quieter than an open-frame diesel, but it's still a diesel engine. Some owners call it fairly quiet, and others find it louder than they expected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I extend the exhaust to reduce the noise?\u003c\/strong\u003e Please don't. Warrior's warranty excludes exhaust extensions, and exhaust gas is dangerous. Choosing a position further away is the safe way to reduce noise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it start automatically?\u003c\/strong\u003e Yes, with the optional \u003ca href=\"\/products\/warrior-diesel-ats-100a-automatic-transfer-switch-for-4kw-to-12kw-generators\"\u003eWarrior ATS panel\u003c\/a\u003e, which connects to the port already fitted.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it run a borehole pump?\u003c\/strong\u003e Usually yes, but pumps draw a large current at start-up. Send us your pump's rating and we'll check it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I plug in normal appliances?\u003c\/strong\u003e Not directly. The outlets are industrial-style 32A, so you need a matching plug, a suitable splitter box or a transfer switch.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it start in freezing weather?\u003c\/strong\u003e The manual describes a preheat button for temperatures below 0°C. With the key on, hold it for at least 5 seconds until the red light is solid, then start as normal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I charge a battery from it?\u003c\/strong\u003e Yes, but only 12V car-type batteries using the DC terminals, and never use the DC and AC outputs at the same time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy might it say Bimson Power?\u003c\/strong\u003e Warrior's UK distributor also sells this model under the Bimson Power name, so your generator or its paperwork may carry that branding.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it for everyday use?\u003c\/strong\u003e No. It's designed for backup and infrequent use. For daily running, ask us about a 1500rpm generator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the warranty work?\u003c\/strong\u003e For domestic use, you get parts and labour in year 1 and parts only in year 2, up to 1,000 hours. Commercial use is 1 year or 500 hours. Hire use isn't covered, batteries are limited to 1 year, and carriage for repairs is at your cost. You don't need to register, but keep your proof of purchase and service records.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot sure it's the right size?\u003c\/strong\u003e Send us your appliance list at \u003ca href=\"mailto:sales@generator-uk.co.uk\"\u003esales@generator-uk.co.uk\u003c\/a\u003e or call \u003ca href=\"tel:01744520110\"\u003e01744 520110\u003c\/a\u003e, Monday to Friday, 8:30am to 5pm, and we'll help you size it.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSafety: run outdoors only, at least 1.5m from buildings and well away from doors, windows and vents. Generator exhaust contains carbon monoxide. Let the engine cool before refuelling.\u003c\/em\u003e\u003c\/p\u003e","brand":"Warrior","offers":[{"title":"Default Title","offer_id":56570707935611,"sku":"LDG6500SV","price":3495.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0559\/2793\/1011\/files\/warrior-ldg6500sv-silent-diesel-generator-87d93001-57e5-4fd8-b5ac-0b596a2ed98f.jpg?v=1794173216","url":"https:\/\/generator-uk.co.uk\/products\/warrior-ldg6500sv-5kw-silent-diesel-generator","provider":"Generators UK","version":"1.0","type":"link"}