{"product_id":"pramac-e4000-3-1kw-petrol-generator","title":"Pramac E4000 3.1kW Petrol Generator","description":"\u003cp\u003e\u003cstrong\u003eA Honda GX200 engine in a Pramac frame, light enough to lift on and off the van.\u003c\/strong\u003e The E4000 gives 2.6kW continuous from one of the most trusted small engines in the trade, with two 230V and two 115V outlets ready for site tools. At 36kg with a simple pull start, it has power in place in a minute.\u003c\/p\u003e\n\u003cp\u003e✔ Authorised UK reseller   ✔ Free delivery to mainland UK   ✔ Prices include VAT   ✔ Manufacturer's warranty\u003c\/p\u003e\n\u003ch3\u003eWhy buyers choose the E4000\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHonda GX200 engine.\u003c\/strong\u003e A 196cc four-stroke with a strong reputation among trades and hire companies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtected as standard.\u003c\/strong\u003e Honda's Oil Alert stops the engine before the oil runs too low, and thermal protection guards against overloads and short circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour 16A outlets.\u003c\/strong\u003e Two 230V and two 115V IP44 sockets, so site tools plug straight in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight and compact.\u003c\/strong\u003e At 36kg dry, two people can load it easily, and it fits in a small van.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNothing to charge.\u003c\/strong\u003e Recoil start means no battery to maintain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTough frame.\u003c\/strong\u003e A tubular wrap-around frame with an epoxy powder finish protects it on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIs it right for you?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIdeal for:\u003c\/strong\u003e trades on short jobs, hand tools and site lighting, renovation work, grounds maintenance and anywhere refuelling is easy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLook elsewhere if:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eYou want longer running. The 3.1-litre tank lasts under 3 hours, and the \u003ca href=\"\/products\/jcb-g3600p-3-6kw-dual-voltage-petrol-generator\"\u003eJCB G3600P\u003c\/a\u003e has a 15-litre tank.\u003c\/li\u003e\n\u003cli\u003eYou're powering laptops or other sensitive electronics. This model has no AVR, so choose the \u003ca href=\"\/products\/honda-eu22i-2-2kw-inverter-suitcase-generator\"\u003eHonda EU22i\u003c\/a\u003e or another of our \u003ca href=\"\/collections\/inverter-generators\"\u003einverter generators\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eYou'd rather wheel it. The \u003ca href=\"\/products\/ford-fg4650-q-series-3kw-dual-voltage-petrol-generator\"\u003eFord FG4650\u003c\/a\u003e comes on wheels.\u003c\/li\u003e\n\u003cli\u003eYou need more power. The \u003ca href=\"\/products\/senci-sc6000-ii-5-5kw-electric-start-petrol-generator\"\u003eSenci SC6000-II\u003c\/a\u003e gives 5kW continuous.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat will it run?\u003c\/h3\u003e\n\u003cp\u003ePlan around the \u003cstrong\u003e2.6kW continuous\u003c\/strong\u003e output. The 3.1kW maximum is for short bursts, such as a motor starting. Each 115V 16A socket can supply up to about 1.8kW. In hot weather, Pramac says power falls by about 2% for every 5°C above 20°C.\u003c\/p\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTool or appliance\u003c\/th\u003e\n\u003cth\u003eTypical running watts\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED site lighting\u003c\/td\u003e\n\u003ctd\u003e50 to 300W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCordless tool chargers\u003c\/td\u003e\n\u003ctd\u003e100 to 300W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHammer drill (110V)\u003c\/td\u003e\n\u003ctd\u003e700 to 1,100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDS drill (110V)\u003c\/td\u003e\n\u003ctd\u003e800 to 1,500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAngle grinder or circular saw (higher start-up draw)\u003c\/td\u003e\n\u003ctd\u003e1,200 to 1,800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard 3kW kettle\u003c\/td\u003e\n\u003ctd\u003e3,000W: too much for this generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eExample:\u003c\/strong\u003e site lighting 200W + tool charger 100W + SDS drill 1,200W comes to about 1,500W, which leaves around 1,100W in hand. Check the rating plates on your own tools, as figures vary.\u003c\/p\u003e\n\u003ch3\u003eHow long will the fuel last?\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad\u003c\/th\u003e\n\u003cth\u003eRun time on 3.1 litres\u003c\/th\u003e\n\u003cth\u003eFuel use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e75%\u003c\/td\u003e\n\u003ctd\u003e2.65 hours\u003c\/td\u003e\n\u003ctd\u003e1.17 litres an hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100%\u003c\/td\u003e\n\u003ctd\u003eAbout 2 hours\u003c\/td\u003e\n\u003ctd\u003e1.57 litres an hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eAn eight-hour day at 75% load uses about 9.5 litres, so plan on three fill-ups and keep a \u003ca href=\"\/products\/sealey-jc20b-20-litre-black-steel-jerry-can\"\u003e20-litre jerry can\u003c\/a\u003e to hand. Use unleaded petrol with no more than 10% ethanol, so standard E10 is fine.\u003c\/p\u003e\n\u003ch3\u003eEarthing and connecting it\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDon't earth it as standard.\u003c\/strong\u003e Pramac's manual says the standard generator is protected by electrical separation and must not be earthed through its PE terminal or any other part. If a switchboard or other device is added, the protection and earthing requirements change, so that work is for a qualified electrician.\u003c\/p\u003e\n\u003cp\u003eIt must never be connected to the mains or to another power source unless a qualified electrician carries out a proper changeover installation. Never feed it through a socket. Check any site rules on electrical protection before you use it on a job.\u003c\/p\u003e\n\u003ch3\u003eWhere to put it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRun it on a flat, stable surface, outdoors and well away from doors, windows and vents.\u003c\/li\u003e\n\u003cli\u003eNever run it in a home, garage or van, even with the doors open.\u003c\/li\u003e\n\u003cli\u003eIn rain or snow, it needs firm shelter from the weather, but it must stay well ventilated.\u003c\/li\u003e\n\u003cli\u003eKeep children away from the generator and the fuel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGetting it running\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd engine oil.\u003c\/strong\u003e It's delivered without oil and takes 0.6 litres. Honda recommends SAE 10W-30, API SJ or later, for general use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdd fresh petrol.\u003c\/strong\u003e Stop the engine and let it cool before refuelling, and don't fill right up to the cap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStart with nothing plugged in.\u003c\/strong\u003e Use the choke from cold, pull until you feel resistance, then pull briskly. Guide the cord back gently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse the right plugs.\u003c\/strong\u003e The sockets are 16A industrial-style, so most site tools plug straight in. Household 13A plugs need an adaptor, such as our \u003ca href=\"\/products\/e85315-230v-16a-plug-to-4-x-13a-socket-converter\"\u003e16A to 4 x 13A converter\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlan to carry it.\u003c\/strong\u003e No wheels are listed as standard. Ask us if you'd like a trolley kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransport it safely.\u003c\/strong\u003e Pramac says to remove all fuel and strap it down so it can't tip. Never start it inside a van or truck.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDelivery note:\u003c\/strong\u003e Pramac generators can have a longer lead time. If you need one by a certain date, please contact us before ordering and we'll confirm availability.\u003c\/p\u003e\n\u003ch3\u003eKeeping it ready\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eWhen\u003c\/th\u003e\n\u003cth\u003eWhat Honda's engine manual asks for\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBefore each use\u003c\/td\u003e\n\u003ctd\u003eCheck the oil level and air filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirst month or 20 hours\u003c\/td\u003e\n\u003ctd\u003eFirst oil change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvery 3 months or 50 hours\u003c\/td\u003e\n\u003ctd\u003eClean the air filter, more often in dust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvery 6 months or 100 hours\u003c\/td\u003e\n\u003ctd\u003eChange the oil, clean the sediment cup, check the spark plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvery year or 300 hours\u003c\/td\u003e\n\u003ctd\u003eReplace the air filter and spark plug, further engine checks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eOur \u003ca href=\"\/products\/pramac-e3250-and-e4000-generator-service-kit\"\u003eE4000 service kit\u003c\/a\u003e has the oil, filters and spark plug. Keep a record of every service, as Pramac requires proof for a warranty claim. If it will stand for a while, drain the fuel or add a stabiliser, and use a breathable cover, not plastic sheet.\u003c\/p\u003e\n\u003ch3\u003eFull specification\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003ePramac E4000 230\/115V 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct code\u003c\/th\u003e\n\u003ctd\u003ePA292SH1007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003ctd\u003eFrame-mounted petrol generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum output\u003c\/th\u003e\n\u003ctd\u003e3.1kW \/ 3.4kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContinuous output\u003c\/th\u003e\n\u003ctd\u003e2.6kW \/ 2.9kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEngine\u003c\/th\u003e\n\u003ctd\u003eHonda GX200, 196cc, air-cooled, 4-stroke, 3000rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStart\u003c\/th\u003e\n\u003ctd\u003eRecoil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50Hz, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutlets\u003c\/th\u003e\n\u003ctd\u003e2 x 230V 16A, 2 x 115V 16A, IP44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage regulation\u003c\/th\u003e\n\u003ctd\u003eCapacitor (no AVR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection\u003c\/th\u003e\n\u003ctd\u003eOil Alert low-oil shutdown, thermal protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel\u003c\/th\u003e\n\u003ctd\u003eUnleaded petrol, up to 10% ethanol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel tank\u003c\/th\u003e\n\u003ctd\u003e3.1 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRun time\u003c\/th\u003e\n\u003ctd\u003e2.65 hours at 75% load; about 2 hours at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuel use\u003c\/th\u003e\n\u003ctd\u003e1.17 L\/h at 75% load; 1.57 L\/h at 100% load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNoise\u003c\/th\u003e\n\u003ctd\u003e68 dB(A) at 7m; guaranteed sound power 96 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOil\u003c\/th\u003e\n\u003ctd\u003e0.6L, SAE 10W-30 recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e36kg dry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e625 x 455 x 455mm (L x W x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years or 1,000 hours, replacement parts only, per Pramac's warranty statement. Needs proof of purchase and service records. Subject to manufacturer's terms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need an earth rod?\u003c\/strong\u003e Not as standard. Pramac's manual says the standard generator must not be earthed. If you're adding a switchboard or connecting it to a building, ask a qualified electrician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow long will a tank last?\u003c\/strong\u003e About 2.65 hours at 75% load, and around 2 hours at full load. It suits short jobs or places where you can refuel easily.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy did the engine stop by itself?\u003c\/strong\u003e Check the oil first. Oil Alert stops the engine when the level gets too low, and the engine switch stays on when it does.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy have the sockets gone dead?\u003c\/strong\u003e The protection has probably cut the power after an overload or short circuit. Unplug everything, find the cause, then reset it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it run a laptop or TV?\u003c\/strong\u003e It isn't the right choice. It has capacitor regulation rather than AVR, so the voltage is less tightly controlled. An inverter generator is safer for electronics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it good for home backup?\u003c\/strong\u003e It's not ideal, because the small tank needs frequent refuelling during a power cut. Look at a larger tank or diesel model instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the warranty work?\u003c\/strong\u003e Pramac's statement gives E Series generators 2 years or 1,000 hours, with replacement parts only and no labour. Pramac counts cover from factory shipment, so register it promptly and keep your proof of purchase and service records. Non-genuine parts, wrong or stale fuel, modifications, misuse, wrong sizing and damage after delivery aren't covered.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNot sure it's the right size?\u003c\/strong\u003e Send us your tool list at \u003ca href=\"mailto:sales@generator-uk.co.uk\"\u003esales@generator-uk.co.uk\u003c\/a\u003e or call \u003ca href=\"tel:01744520110\"\u003e01744 520110\u003c\/a\u003e, Monday to Friday, 8:30am to 5pm, and we'll help you size it.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSafety: run outdoors only, well away from doors, windows and vents. Generator exhaust contains carbon monoxide. Let the engine cool before refuelling, and never use water on a generator fire.\u003c\/em\u003e\u003c\/p\u003e","brand":"Pramac","offers":[{"title":"Default Title","offer_id":56570709148027,"sku":"E4000","price":1499.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0559\/2793\/1011\/files\/pramac-e4000-petrol-generator-5280c869-1659-4447-9da2-10a9ec542a3c.jpg?v=1794173260","url":"https:\/\/generator-uk.co.uk\/products\/pramac-e4000-3-1kw-petrol-generator","provider":"Generators UK","version":"1.0","type":"link"}