
Ford FD6700S 5kW Canopied Diesel Generator
- Continuous
- 4.5kW
- Noise
- 72 dB(A) at 7m
- Weight
- 165kg
£2,449.98
View this sizePower cut at 2am? Turn the key and keep your home running until morning, and well beyond. The Hyundai DHY8000SELR pairs 5kW of continuous diesel power with a 25-litre long run tank that burns roughly a litre an hour, so you won't be refuelling in the dark. With the optional ATS, it can even start itself.
✔ Authorised UK reseller ✔ Free delivery to mainland UK ✔ Prices include VAT ✔ 1-year Hyundai warranty
Ideal for: home standby power, rural properties on overhead lines, farms, workshops and small premises that need essential circuits kept live.
Look elsewhere if:
Plan around the 5kW continuous figure, not the 5.8kW maximum. These are typical running loads, so check your own appliance labels.
| Appliance | Typical running watts |
|---|---|
| Fridge freezer (higher start-up draw) | around 150W |
| Gas boiler and pump | around 200W |
| LED lighting, whole home | around 100W |
| Router, TV and chargers | around 200W |
| Microwave | around 1,000W |
| Kettle | around 3,000W |
| Electric shower | 7,500W and up: too much for this generator |
Example: fridge freezer, boiler, lights, router and TV come to about 650W, leaving over 4kW spare for cooking or a kettle. Start your largest motor load first.
On 115V: dual-voltage generators give only around 50 to 60% of their rated output on the lower voltage, so plan on about 2.5 to 3kW.
| Load | Fuel use | Run time on 25 litres |
|---|---|---|
| Typical household backup | About 1 litre an hour | Up to 25 hours |
| Full load | 1.71 litres an hour | About 14.6 hours |
Use standard-specification diesel, and never petrol. The engine can take red or white diesel, but the rules on who can use red diesel changed in 2022, so check it's allowed for your use. One owner found the fuel gauge read empty with fuel still in the tank, so treat it as a guide.
To power your home's circuits, the generator must connect through a transfer switch fitted by a qualified electrician, so that it and the mains can never be connected together. Never feed it through a socket.
None of these is included, so ask us which suits your property.
| When | What to do |
|---|---|
| Daily when in use | Check the oil and top up if needed, as these engines use a little. Check diesel, leaks and fastenings |
| First month or 20 hours | First oil change, and first valve clearance adjustment |
| Every 100 hours | Change the oil, wash the oil filter in solvent, check the battery |
| Every 300 hours | Replace the oil, air and fuel filters |
| Every 1,000 hours or yearly | Check valve clearance, injector, fuel pump and pipes |
Keep a record of the date and hours of every service, as Hyundai can ask for it on a warranty claim. Run it regularly between power cuts so that it's ready when you need it.
| Model | Hyundai DHY8000SELR |
|---|---|
| Type | Canopied long run diesel standby generator |
| Maximum output | 5.8kW / 7.25kVA |
| Continuous output | 5.0kW / 6.3kVA |
| Engine | Hyundai D452 series, 456cc, 4-stroke, air-cooled, 3000rpm |
| Fuel / tank | Diesel / 25L |
| Run time | Up to 25 hours at about 1L an hour; about 14.6 hours at full load |
| Voltage / phase | 230V and 115V, single phase, 50Hz |
| Outlets | 1 x 230V 32A, 1 x 115V 32A, 1 x 115V 16A, 1 x 12V DC |
| Start | Electric key start; 12V 36Ah battery |
| ATS | Compatible, optional and not included |
| AVR | Yes |
| Display | Digital control panel display |
| Noise | 70 dB(A) at 7m and 75% load; 96 dB at 1m |
| Weight | 158kg, or 167kg packed |
| Dimensions | 960 x 560 x 890mm (L x W x H) |
| Oil | 1.65L, SAE 15W-40 recommended; 10W-30 to 15W-40, API CH-4/CF/SJ/SL or higher |
| Wheels | Wheel kit |
| Warranty | 1 year or 1,000 hours for home or commercial use, 90 days for hire. Subject to manufacturer's terms |
Can it start automatically in a power cut? Yes, when paired with a compatible ATS, which is an optional extra. Without one, you start it with the key.
How quiet is it? It's much quieter than an open-frame set, but it's still a diesel engine. Some owners found it noisier than they expected, especially when new, so site it away from bedrooms and neighbours.
Why won't it start? On a new machine, check the battery terminals are connected, the oil is filled and the fuel line has been bled. It may also need bleeding if it has run out of diesel.
Can I plug in normal household appliances? Not directly. The outlets are industrial-style 16A and 32A, so you need a suitable adaptor or a transfer switch.
Can it run all day, every day? No. It's designed for standby use. For frequent or continuous power, Hyundai recommends a 1500rpm generator.
Can it back up the whole house? It will run essential circuits, but not everything at once, so an electrician should help you choose which circuits to connect.
How does the warranty work? Home and commercial use are covered for 1 year or 1,000 hours, and hire use for 90 days. Keep your proof of purchase and service records. Overloading, underloading, water or frost damage, stale or contaminated fuel, lack of servicing and modifications aren't covered.
Not sure it's the right size? Send us your appliance list at sales@generator-uk.co.uk or call 01744 520110, Monday to Friday, 8:30am to 5pm, and we'll help you size it.
Safety: run outdoors only, at least 1m from buildings and well away from doors, windows and vents. Generator exhaust contains carbon monoxide. Let the engine cool before refuelling.
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Includes VAT and free mainland UK delivery
Overview
Power cut at 2am? Turn the key and keep your home running until morning, and well beyond. The Hyundai DHY8000SELR pairs 5kW of continuous diesel power with a 25-litre long run tank that burns roughly a litre an hour, so you won't be refuelling in the dark. With the optional ATS, it can even start itself.
✔ Authorised UK reseller ✔ Free delivery to mainland UK ✔ Prices include VAT ✔ 1-year Hyundai warranty
Ideal for: home standby power, rural properties on overhead lines, farms, workshops and small premises that need essential circuits kept live.
Look elsewhere if:
Tap everything you want to run at the same time. We check it against this generator’s real ratings.
Plan around the 5kW continuous figure, not the 5.8kW maximum. These are typical running loads, so check your own appliance labels.
| Appliance | Typical running watts |
|---|---|
| Fridge freezer (higher start-up draw) | around 150W |
| Gas boiler and pump | around 200W |
| LED lighting, whole home | around 100W |
| Router, TV and chargers | around 200W |
| Microwave | around 1,000W |
| Kettle | around 3,000W |
| Electric shower | 7,500W and up: too much for this generator |
Example: fridge freezer, boiler, lights, router and TV come to about 650W, leaving over 4kW spare for cooking or a kettle. Start your largest motor load first.
On 115V: dual-voltage generators give only around 50 to 60% of their rated output on the lower voltage, so plan on about 2.5 to 3kW.
| Load | Fuel use | Run time on 25 litres |
|---|---|---|
| Typical household backup | About 1 litre an hour | Up to 25 hours |
| Full load | 1.71 litres an hour | About 14.6 hours |
Use standard-specification diesel, and never petrol. The engine can take red or white diesel, but the rules on who can use red diesel changed in 2022, so check it's allowed for your use. One owner found the fuel gauge read empty with fuel still in the tank, so treat it as a guide.
To power your home's circuits, the generator must connect through a transfer switch fitted by a qualified electrician, so that it and the mains can never be connected together. Never feed it through a socket.
None of these is included, so ask us which suits your property.
| When | What to do |
|---|---|
| Daily when in use | Check the oil and top up if needed, as these engines use a little. Check diesel, leaks and fastenings |
| First month or 20 hours | First oil change, and first valve clearance adjustment |
| Every 100 hours | Change the oil, wash the oil filter in solvent, check the battery |
| Every 300 hours | Replace the oil, air and fuel filters |
| Every 1,000 hours or yearly | Check valve clearance, injector, fuel pump and pipes |
Keep a record of the date and hours of every service, as Hyundai can ask for it on a warranty claim. Run it regularly between power cuts so that it's ready when you need it.
Data sheet
| Model | Hyundai DHY8000SELR |
|---|---|
| Type | Canopied long run diesel standby generator |
| Maximum output | 5.8kW / 7.25kVA |
| Continuous output | 5.0kW / 6.3kVA |
| Engine | Hyundai D452 series, 456cc, 4-stroke, air-cooled, 3000rpm |
| Fuel / tank | Diesel / 25L |
| Run time | Up to 25 hours at about 1L an hour; about 14.6 hours at full load |
| Voltage / phase | 230V and 115V, single phase, 50Hz |
| Outlets | 1 x 230V 32A, 1 x 115V 32A, 1 x 115V 16A, 1 x 12V DC |
| Start | Electric key start; 12V 36Ah battery |
| ATS | Compatible, optional and not included |
| AVR | Yes |
| Display | Digital control panel display |
| Noise | 70 dB(A) at 7m and 75% load; 96 dB at 1m |
| Weight | 158kg, or 167kg packed |
| Dimensions | 960 x 560 x 890mm (L x W x H) |
| Oil | 1.65L, SAE 15W-40 recommended; 10W-30 to 15W-40, API CH-4/CF/SJ/SL or higher |
| Wheels | Wheel kit |
| Warranty | 1 year or 1,000 hours for home or commercial use, 90 days for hire. Subject to manufacturer's terms |
Right size?

£2,449.98
View this size
£3,375.00

£3,999.98
View this sizeQuestions
Safety: run outdoors only, at least 1m from buildings and well away from doors, windows and vents. Generator exhaust contains carbon monoxide. Let the engine cool before refuelling.
Complete your setup
Checked against this generator’s sockets and fuel.



