
Ford FD6700S 5kW Canopied Diesel Generator
- Continuous
- 4.5kW
- Noise
- 72 dB(A) at 7m
- Weight
- 165kg
£2,449.98
View this sizeWhen the lines go down, turn a key and get 5kW of diesel power back. The Warrior LDG6500SV keeps an oil boiler, borehole pump and the rest of your essentials running from a soundproofed canopy, with up to 12.4 hours from a half-loaded tank. It also has a port ready for automatic start, which the remote-control version doesn't.
✔ Authorised UK reseller ✔ Free delivery to mainland UK ✔ Prices include VAT ✔ 2-year warranty
Ideal for: power cut backup at rural homes, off-grid and island properties, oil boilers and borehole pumps, small premises, and occasional construction or catering jobs.
Look elsewhere if:
Plan around the 5kW continuous output. The 5.5kW maximum is only for short bursts, and the manual says never to run at maximum for longer than 10 minutes. Motors can draw three times their running watts or more when starting, so check the rating plates on your own equipment.
| Appliance | Typical running watts |
|---|---|
| LED lighting, whole home | 100 to 300W |
| Router, TV and chargers | around 200W |
| Fridge freezer (higher start-up draw) | 150 to 300W |
| Oil-fired boiler and pump | around 250W |
| Borehole pump (much higher start-up draw) | 750 to 1,500W |
| Microwave | 1,200 to 1,600W |
| Washing machine | 2,100 to 2,400W |
| Kettle | 2,500 to 3,000W |
| Electric shower | 7,500W and up: too much for this generator |
Rural home example: oil boiler 250W + 1,000W borehole pump + fridge freezer 150W + lights 100W + TV and router 200W comes to about 1,700W, which leaves around 3,300W in hand. If the pump pulls three times its running watts as it starts, the brief peak is about 3,700W, still inside the 5kW rating. Start the pump first, then bring on other loads.
On the 110V outlet: expect only around 50 to 60% of the rated output, so about 2.5 to 3kW.
At half load, a 24-hour power cut will take about two full tanks, or 32 litres. Lighter loads last longer and heavier loads less. Keeping fuel on site makes sense if you're rural, and a 20-litre steel jerry can is a good start.
Use clean light diesel only. Never use petrol, kerosene or biodiesel. Warrior doesn't recommend dyed diesel, such as red diesel, and if you do use it, the manual strongly recommends monthly maintenance.
To power your property's circuits, the generator must connect through a transfer switch fitted by a qualified electrician, so that it and the mains can never be connected together. Never feed it through a socket. Neither switch is included.
Important for your warranty: Warrior's terms say that any manual or automatic transfer system not supplied under the Warrior or Champion name will invalidate all warranties. Please speak to us before you buy or install one.
Delivery note: Warrior generators can take 2 to 5 working days to arrive. If you need one by a certain date, please contact us before ordering and we'll confirm availability.
| When | What the manual asks for |
|---|---|
| Before each use | Check oil and fuel, look for leaks and loose parts |
| After the first 20 hours | First oil change, drain the fuel tank, check valve clearances |
| Monthly | Check battery fluid and air filter |
| Every 100 hours or 3 months | Change oil, clean oil filter |
| Every 300 hours or 6 months | Replace oil and air filters, clean fuel filter, further engine checks |
| Every 1,000 hours or annually | Replace fuel filter, further engine servicing |
Start it regularly between power cuts so that it's ready when you need it. Some items need a service engineer, and the manual marks which ones.
| Model | Warrior LDG6500SV (Bimson Power range) |
|---|---|
| Type | Canopied silent diesel generator |
| Maximum output | 5.5kW / 6.25kVA |
| Continuous output | 5.0kW |
| Engine | 474cc, single cylinder, air-cooled, direct injection, 3000rpm |
| Emissions | EU Stage V |
| Alternator | Brushed copper, AVR regulated |
| Start | Electric key start; ATS input port |
| Voltage / phase | 240V and 110V, single phase, 50Hz |
| Outlets | 1 x 240V 32A, 1 x 110V 32A, 12V DC charging terminal |
| Protection | Automatic low-oil shutdown, overload protection, AVR |
| Display | 3-in-1: voltage, frequency and run time; fuel gauge |
| Fuel / tank | Light diesel / 16 litres |
| Run time | Up to 12.4 hours at 50% load |
| Noise | 68 dB(A) at 7m |
| Oil | 1.1L, 10W-30 part or full synthetic recommended |
| Wheels | Included |
| Weight | 168kg |
| Dimensions | 880 x 590 x 730mm (L x W x H) |
| In the box | Generator and operating manual |
| Certification | EU Stage V, UKCA, GS, TUV |
| Warranty | 2 years domestic: year 1 parts and labour, year 2 parts only, or 1,000 hours if sooner. Subject to manufacturer's terms |
Is it really silent? "Silent" is the name for this canopied design. It's much quieter than an open-frame diesel, but it's still a diesel engine. Some owners call it fairly quiet, and others find it louder than they expected.
Can I extend the exhaust to reduce the noise? Please don't. Warrior's warranty excludes exhaust extensions, and exhaust gas is dangerous. Choosing a position further away is the safe way to reduce noise.
Can it start automatically? Yes, with the optional Warrior ATS panel, which connects to the port already fitted.
Will it run a borehole pump? Usually yes, but pumps draw a large current at start-up. Send us your pump's rating and we'll check it.
Can I plug in normal appliances? Not directly. The outlets are industrial-style 32A, so you need a matching plug, a suitable splitter box or a transfer switch.
Will it start in freezing weather? The manual describes a preheat button for temperatures below 0°C. With the key on, hold it for at least 5 seconds until the red light is solid, then start as normal.
Can I charge a battery from it? Yes, but only 12V car-type batteries using the DC terminals, and never use the DC and AC outputs at the same time.
Why might it say Bimson Power? Warrior's UK distributor also sells this model under the Bimson Power name, so your generator or its paperwork may carry that branding.
Is it for everyday use? No. It's designed for backup and infrequent use. For daily running, ask us about a 1500rpm generator.
How does the warranty work? For domestic use, you get parts and labour in year 1 and parts only in year 2, up to 1,000 hours. Commercial use is 1 year or 500 hours. Hire use isn't covered, batteries are limited to 1 year, and carriage for repairs is at your cost. You don't need to register, but keep your proof of purchase and service records.
Not sure it's the right size? Send us your appliance list at sales@generator-uk.co.uk or call 01744 520110, Monday to Friday, 8:30am to 5pm, and we'll help you size it.
Safety: run outdoors only, at least 1.5m from buildings and well away from doors, windows and vents. Generator exhaust contains carbon monoxide. Let the engine cool before refuelling.
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Includes VAT and free mainland UK delivery
Overview
When the lines go down, turn a key and get 5kW of diesel power back. The Warrior LDG6500SV keeps an oil boiler, borehole pump and the rest of your essentials running from a soundproofed canopy, with up to 12.4 hours from a half-loaded tank. It also has a port ready for automatic start, which the remote-control version doesn't.
✔ Authorised UK reseller ✔ Free delivery to mainland UK ✔ Prices include VAT ✔ 2-year warranty
Ideal for: power cut backup at rural homes, off-grid and island properties, oil boilers and borehole pumps, small premises, and occasional construction or catering jobs.
Look elsewhere if:
Tap everything you want to run at the same time. We check it against this generator’s real ratings.
Plan around the 5kW continuous output. The 5.5kW maximum is only for short bursts, and the manual says never to run at maximum for longer than 10 minutes. Motors can draw three times their running watts or more when starting, so check the rating plates on your own equipment.
| Appliance | Typical running watts |
|---|---|
| LED lighting, whole home | 100 to 300W |
| Router, TV and chargers | around 200W |
| Fridge freezer (higher start-up draw) | 150 to 300W |
| Oil-fired boiler and pump | around 250W |
| Borehole pump (much higher start-up draw) | 750 to 1,500W |
| Microwave | 1,200 to 1,600W |
| Washing machine | 2,100 to 2,400W |
| Kettle | 2,500 to 3,000W |
| Electric shower | 7,500W and up: too much for this generator |
Rural home example: oil boiler 250W + 1,000W borehole pump + fridge freezer 150W + lights 100W + TV and router 200W comes to about 1,700W, which leaves around 3,300W in hand. If the pump pulls three times its running watts as it starts, the brief peak is about 3,700W, still inside the 5kW rating. Start the pump first, then bring on other loads.
On the 110V outlet: expect only around 50 to 60% of the rated output, so about 2.5 to 3kW.
At half load, a 24-hour power cut will take about two full tanks, or 32 litres. Lighter loads last longer and heavier loads less. Keeping fuel on site makes sense if you're rural, and a 20-litre steel jerry can is a good start.
Use clean light diesel only. Never use petrol, kerosene or biodiesel. Warrior doesn't recommend dyed diesel, such as red diesel, and if you do use it, the manual strongly recommends monthly maintenance.
To power your property's circuits, the generator must connect through a transfer switch fitted by a qualified electrician, so that it and the mains can never be connected together. Never feed it through a socket. Neither switch is included.
Important for your warranty: Warrior's terms say that any manual or automatic transfer system not supplied under the Warrior or Champion name will invalidate all warranties. Please speak to us before you buy or install one.
Delivery note: Warrior generators can take 2 to 5 working days to arrive. If you need one by a certain date, please contact us before ordering and we'll confirm availability.
| When | What the manual asks for |
|---|---|
| Before each use | Check oil and fuel, look for leaks and loose parts |
| After the first 20 hours | First oil change, drain the fuel tank, check valve clearances |
| Monthly | Check battery fluid and air filter |
| Every 100 hours or 3 months | Change oil, clean oil filter |
| Every 300 hours or 6 months | Replace oil and air filters, clean fuel filter, further engine checks |
| Every 1,000 hours or annually | Replace fuel filter, further engine servicing |
Start it regularly between power cuts so that it's ready when you need it. Some items need a service engineer, and the manual marks which ones.
Data sheet
| Model | Warrior LDG6500SV (Bimson Power range) |
|---|---|
| Type | Canopied silent diesel generator |
| Maximum output | 5.5kW / 6.25kVA |
| Continuous output | 5.0kW |
| Engine | 474cc, single cylinder, air-cooled, direct injection, 3000rpm |
| Emissions | EU Stage V |
| Alternator | Brushed copper, AVR regulated |
| Start | Electric key start; ATS input port |
| Voltage / phase | 240V and 110V, single phase, 50Hz |
| Outlets | 1 x 240V 32A, 1 x 110V 32A, 12V DC charging terminal |
| Protection | Automatic low-oil shutdown, overload protection, AVR |
| Display | 3-in-1: voltage, frequency and run time; fuel gauge |
| Fuel / tank | Light diesel / 16 litres |
| Run time | Up to 12.4 hours at 50% load |
| Noise | 68 dB(A) at 7m |
| Oil | 1.1L, 10W-30 part or full synthetic recommended |
| Wheels | Included |
| Weight | 168kg |
| Dimensions | 880 x 590 x 730mm (L x W x H) |
| In the box | Generator and operating manual |
| Certification | EU Stage V, UKCA, GS, TUV |
| Warranty | 2 years domestic: year 1 parts and labour, year 2 parts only, or 1,000 hours if sooner. Subject to manufacturer's terms |
Right size?

£2,449.98
View this size
£3,495.00

£3,999.98
View this sizeQuestions
Safety: run outdoors only, at least 1.5m from buildings and well away from doors, windows and vents. Generator exhaust contains carbon monoxide. Let the engine cool before refuelling.
Complete your setup
Checked against this generator’s sockets and fuel.




